  "scope": "Primary evidence for distinctions, not numerical calibration. Existing anatomy bibliography unchanged.",
  "sources": [
    {
      "id": "murray2000",
      "authors": "Murray, Buchanan and Delp",
      "title": "The isometric functional capacity of muscles that cross the elbow",
      "year": 2000,
      "url": "https://research.me.udel.edu/buchanan/PDF_Files/Murray,%20Buchanan,%20Delp,%20JB%202000.pdf",
      "doi": "10.1016/S0021-9290(00)00051-8",
      "source_kind": "original human cadaveric study",
      "access_on": "2026-10-08",
      "access_scope": "Full text read; Methods pp. 944\u2013946, Table 2 p. 947",
      "supported_use": "PCSA is V/optimal fascicle length; pennation projection is separate. Ten extremities from nine cadavers, with muscle-specific exclusions.",
      "transfer_limit": "No subject-matched atlas calibration; no muscle architecture values imported.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "ward2005",
      "authors": "Ward and Lieber",
      "title": "Density and hydration of fresh and fixed human skeletal muscle",
      "year": 2005,
      "url": "https://muscle2.ucsd.edu/pubs/pdf/Ward_JB_2005a.pdf",
      "doi": "10.1016/j.jbiomech.2004.10.001",
      "source_kind": "original human tissue preparation study",
      "access_on": "2026-10-08",
      "access_scope": "Full text read; equation 1 and Results",
      "supported_use": "PCSA definition includes cosine; density depends on preparation.",
      "transfer_limit": "Fixed/hydrated tissue findings are not a measured live-biceps density; no density imported.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "mattiello2023",
      "authors": "Mattiello-Sverzut and Martins",
      "title": "Does the early phase of aging affect the morphology of biceps brachii and torque and total work of elbow flexors in healthy volunteers?",
      "year": 2023,
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC9925190/",
      "doi": "10.1590/1414-431X2023e12202",
      "source_kind": "original human biopsy study",
      "access_on": "2026-10-08",
      "access_scope": "PubMed abstract read; morphology participant counts verified from original full text in independent source review; direct reaccess returned a browser challenge",
      "supported_use": "Thirty-two participants underwent isokinetic assessment; 26 usable morphology samples (9, 8, and 9 across the age groups) support fibre-subtype and smaller-diameter comparisons.",
      "transfer_limit": "No fresh full-text diameter extraction or packing calibration; diameter is not silently converted to circular area.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "bottinelli1996",
      "authors": "Bottinelli, Canepari, Pellegrino and Reggiani",
      "title": "Force-velocity properties of human skeletal muscle fibres: myosin heavy chain isoform and temperature dependence",
      "year": 1996,
      "url": "https://physoc.onlinelibrary.wiley.com/doi/10.1113/jphysiol.1996.sp021617",
      "doi": "10.1113/jphysiol.1996.sp021617",
      "source_kind": "original human skinned fibre experiment",
      "access_on": "2026-10-08",
      "access_scope": "Publisher abstract read",
      "supported_use": "Single-fibre specific tension and velocity depend on type and preparation temperature; load clamps at 12 \u00b0C.",
      "transfer_limit": "No body-temperature extrapolation, type-specific numerical parameters or whole-muscle fit.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "raiteri2016",
      "authors": "Raiteri, Cresswell and Lichtwark",
      "title": "Three-dimensional geometrical changes of the human tibialis anterior muscle and its central aponeurosis measured with three-dimensional ultrasound during isometric contractions",
      "year": 2016,
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC4974924/",
      "doi": "10.7717/peerj.2260",
      "source_kind": "original human 3D ultrasound study",
      "access_on": "2026-10-08",
      "access_scope": "Indexed primary article text read; direct PMC access subsequently challenged",
      "supported_use": "Regional geometry, fascicle length and pennation are distinct measured quantities.",
      "transfer_limit": "Tibialis anterior is not biceps; near-constant total volume is not local incompressibility. No values imported.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "huijing2003",
      "authors": "Huijing and Baan",
      "title": "Myofascial force transmission: muscle relative position and length determine agonist and synergist muscle force",
      "year": 2003,
      "url": "https://pubmed.ncbi.nlm.nih.gov/12571138/",
      "doi": "10.1152/japplphysiol.00173.2002",
      "source_kind": "original rat experiment",
      "access_on": "2026-10-08",
      "access_scope": "PubMed abstract read",
      "supported_use": "Proximal and distal forces differed with connective tissues intact and controlled muscle length/position.",
      "transfer_limit": "Maximal rat activation under manipulated conditions does not calibrate normal human biceps ECM.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "zhang2012",
      "authors": "Zhang and Gao",
      "title": "Finite element analysis of mechanics of lateral transmission of force in single muscle fiber",
      "year": 2012,
      "url": "https://pubmed.ncbi.nlm.nih.gov/22682257/",
      "doi": "10.1016/j.jbiomech.2012.04.026",
      "source_kind": "original two-dimensional finite element study",
      "access_on": "2026-10-08",
      "access_scope": "PubMed abstract and figure descriptions read",
      "supported_use": "Examines endomysium shear transfer and tapered fibre ends.",
      "transfer_limit": "Computational mechanism, not an experimental human interface stiffness.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "sleboda2020",
      "authors": "Sleboda and Roberts",
      "title": "Internal fluid pressure influences muscle contractile force",
      "year": 2020,
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC6983394/",
      "doi": "10.1073/pnas.1914433117",
      "source_kind": "original bullfrog experiment and physical analogue",
      "access_on": "2026-10-08",
      "access_scope": "Full text read; experimental perturbation, Results and Discussion",
      "supported_use": "Cuff pressure changes force in a length-dependent way; fluid\u2013ECM paths need explicit modeling.",
      "transfer_limit": "No unique mechanism identification, biceps calibration or perfusion law; no pressure values imported.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    },
    {
      "id": "cat-perfusion1984",
      "authors": "Petrofsky and Hendershot",
      "title": "The interrelationship between blood pressure, intramuscular pressure, and isometric endurance in fast and slow twitch skeletal muscle in the cat",
      "year": 1984,
      "url": "https://pubmed.ncbi.nlm.nih.gov/6542507/",
      "doi": "10.1007/BF00422571",
      "source_kind": "original cat perfusion experiment",
      "access_on": "2026-10-08",
      "access_scope": "Indexed PubMed abstract read; direct page returned no article body",
      "supported_use": "Compares pressure/perfusion and isometric endurance under controlled perfusion conditions.",
      "transfer_limit": "No parameters imported; cannot infer vascular flow from bulk penalty or volume preservation.",
      "numerical_parameter_imported": false,
      "redistribution": "Bibliographic metadata and original summaries only; no source asset copied."
    }
  ]
}